5A Rogowski Integrator Kit
Flexible rope-style Rogowski coil CT with 5A output for any 5A input meter or equipment



Step 1: Select a Series Model:
Note: Free shipping to US continental and Canada for orders $50.00 and above.
Priced from:
$750 – $1,245.00 USD
Select a Model for Pricing
Looking for volume pricing?
Customize Any Order
Need something specific? We'll customize any order to fit your needs.
RIK 5A Series Models
The Rogowski Integrator Kit comes with a choice of optional current transformer sizes.
Rogowski CT Specifications | RIK16-5A |
---|---|
Window Diameter Size in (mm) | 4.17 (106) |
Length in (mm) | 15.75 (400) |
Current Measurement Range | 2.5A – 60000A |
Output Current | 0 – 6A RMS (0 – 5A RMS Nominal) |
Sensing Range | 500A, 1000A, 2500A, 5000A, 10000A, 25000A and 50000A (user selectable) |
Maximum Burden | 1.8VA/channel |
Maximum Output Impedance | 50mΩ |
Measurement Channels | 3 (three-phase or single-phase) |
Frequency | 45Hz to 65Hz |
Accuracy | ±1% Full Scale Error |
Channel Cross Talk | < -60dB |
Maximum Operating Temperature | 55°C (131°F) |
Rogowski CT Specifications | RIK24-5A |
---|---|
Window Diameter Size in (mm) | 7.01(178) |
Length in (mm) | 23.62 (600) |
Current Measurement Range | 2.5A – 60000A |
Output Current | 0 – 6A RMS (0 – 5A RMS Nominal) |
Sensing Range | 500A, 1000A, 2500A, 5000A, 10000A, 25000A and 50000A (user selectable) |
Maximum Burden | 1.8VA/channel |
Maximum Output Impedance | 50mΩ |
Measurement Channels | 3 (three-phase or single-phase) |
Frequency | 45Hz to 65Hz |
Accuracy | ±1% Full Scale Error |
Channel Cross Talk | < -60dB |
Maximum Operating Temperature | 55°C (131°F) |
Rogowski CT Specifications | RIK36-5A |
---|---|
Window Diameter Size in (mm) | 10.67 (271) |
Length in (mm) | 35.43 (900) |
Current Measurement Range | 2.5A – 60000A |
Output Current | 0 – 6A RMS (0 – 5A RMS Nominal) |
Sensing Range | 500A, 1000A, 2500A, 5000A, 10000A, 25000A and 50000A (user selectable) |
Maximum Burden | 1.8VA/channel |
Maximum Output Impedance | 50mΩ |
Measurement Channels | 3 (three-phase or single-phase) |
Frequency | 45Hz to 65Hz |
Accuracy | ±1% Full Scale Error |
Channel Cross Talk | < -60dB |
Maximum Operating Temperature | 55°C (131°F) |
Rogowski CT Specifications | RIK47-5A |
---|---|
Window Diameter Size in (mm) | 14.53 (369) |
Length in (mm) | 47.24 (1200) |
Current Measurement Range | 2.5A – 60000A |
Output Current | 0 – 6A RMS (0 – 5A RMS Nominal) |
Sensing Range | 500A, 1000A, 2500A, 5000A, 10000A, 25000A and 50000A (user selectable) |
Maximum Burden | 1.8VA/channel |
Maximum Output Impedance | 50mΩ |
Measurement Channels | 3 (three-phase or single-phase) |
Frequency | 45Hz to 65Hz |
Accuracy | ±1% Full Scale Error |
Channel Cross Talk | < -60dB |
Maximum Operating Temperature | 55°C (131°F) |